29.5.17 FiberFacilityMappingPart
Topic Version | 1 | Published | 12/09/2016 | ||
For Standard | PRODML v2.0 | ||||
Type: | Class | Stereotype: | «XSDcomplexType» |
Relates distances measured along the optical path to specific lengths along facilities (wellbores or pipelines).
Name |
Type |
Notes |
---|---|---|
Comment |
String2000 |
A descriptive remark about the facility mapping. |
FacilityLengthEnd |
LengthMeasure |
Distance between the facility datum and the distance where the mapping with the optical path ends. |
FacilityLengthStart |
LengthMeasure |
Distance between the facility datum and the distance where the mapping with the optical path takes place. |
OpticalPathDistanceEnd |
LengthMeasure |
Distance between the beginning of the optical path to the distance where the mapping with the facility ends. |
OpticalPathDistanceStart |
LengthMeasure |
Distance between the beginning of the optical path to the distance where the mapping with the facility takes place. |
uid |
String64 |
Unique identifier or this object. |
Association |
Notes |
---|---|
From: FiberFacilityMappingPart.FiberFacility 1..1To: AbstractFiberFacility Association |
|
From: FiberFacilityMapping.FiberFacilityMappingPart 1..*To: FiberFacilityMappingPart Association |