29.6.6 ConstantCompositionExpansionTest
Topic Version | 1 | Published | 12/09/2016 | ||
For Standard | PRODML v2.0 | ||||
Type: | Class | Stereotype: | «XSDcomplexType» |
The CCE test
Name |
Type |
Notes |
---|---|---|
ConstantCompositionExpansionTestStep |
ConstantCompositionExpansionTestStep |
Measured relative volume ratio = measured volume/volume at Psat. |
LiquidFractionReference |
FluidVolumeReference |
Volume reference for the measured liquid fraction in a constant composition expansion test. Referenced to liquid volume at saturation pressure (generally). |
RelativeVolumeReference |
FluidVolumeReference |
Volume reference for the relative volume ratio in a constant composition expansion test. Referenced to liquid volume at saturation pressure (generally). |
Remark |
String2000 |
Expected to be a yes or no value to indicate if differential liberation/vaporization data are corrected to separator conditions/flash data or not. |
SaturationPressure |
SaturationPressure |
The saturation (or bubble point) pressure measured in this test. |
TestNumber |
NonNegativeLong |
A number for this test for purposes of e.g., tracking lab sequence. |
TestTemperature |
ThermodynamicTemperatureMeasure |
The temperature of this test. |
uid |
String64 |
A unique identifier for this data element. It is not globally unique (not a uuid) and only need be unique within the context of the parent top-level object. |
Association |
Notes |
---|---|
From: ConstantCompositionExpansionTest. To: ConstantCompositionExpansionTestStep Dependency |
|
From: HydrocarbonAnalysis. To: ConstantCompositionExpansionTest Dependency |