29.6.8 ConstantVolumeDepletionTest

Topic Version1Published12/09/2016
For StandardPRODML v2.0
Type:ClassStereotype:«XSDcomplexType»

The CVT test.

Table 29.6.8-1 Attributes

Name

Type

Notes

CumulativeGasProducedReferenceStd

VolumeMeasure

The volume is corrected to standard conditions of temperature and pressure.

Remark

String2000

Remarks and comments about this data item.

TestNumber

NonNegativeLong

A number for this test for purposes of, e.g., tracking lab sequence.

TestTemperature

ThermodynamicTemperatureMeasure

The temperature of this test.

uid

String64

A unique identifier for this data element. It is not globally unique (not a uuid) and only need be unique within the context of the parent top-level object.

Table 29.6.8-2 Associations

Association

Notes

From: ConstantVolumeDepletionTest.LiquidDropoutReference

0..*To: FluidVolumeReference

Association

 

From: ConstantVolumeDepletionTest.SatuationPressure

0..1To: SaturationPressure

Association

 

From: ConstantVolumeDepletionTest.CvdTestStep

0..*To: FluidCvdTestStep

Association

 

From: HydrocarbonAnalysis.

To: ConstantVolumeDepletionTest

Dependency