29.9.5 SeparatorSampleAcquisition
| Topic Version | 1 | Published | 12/09/2016 | ||
| For Standard | PRODML v2.0 | ||||
| Type: | Class | Stereotype: | «XSDcomplexType» | ||
Additonal information required from a fluid sample taken from a separator.
|
Name |
Type |
Notes |
|---|---|---|
|
CorrectedGasRate |
VolumePerTimeMeasure |
The corrected gas rate for this separator sample acquisition. |
|
CorrectedOilRate |
VolumePerTimeMeasure |
The corrected oil rate for this separator sample acquisition. |
|
CorrectedWaterRate |
VolumePerTimeMeasure |
The corrected water rate for this separator sample acquisition. |
|
MeasuredGasRate |
VolumePerTimeMeasure |
The measured gas rate for this separator sample acquisition. |
|
MeasuredOilRate |
VolumePerTimeMeasure |
The measured oil rate for this separator sample acquisition. |
|
MeasuredWaterRate |
VolumePerTimeMeasure |
The measured water rate for this separator sample acquisition. |
|
SamplingPoint |
String64 |
A reference to the flow port in the facility where this sample was taken. |
|
Separator |
String64 |
A reference to the separator where this sample was taken. |
|
SeparatorPressure |
AbstractPressureValue |
The separator pressure when this sample was taken. |
|
SeparatorTemperature |
ThermodynamicTemperatureMeasure |
The separator temperature when this sample was taken. |
|
WellCompletionReference |
DataObjectReference |
A reference to a well completion (WITSML data object) where this sample was taken. |
|
Association |
Notes |
|---|---|
|
From: SeparatorSampleAcquisition. To: FluidSampleAcquisition Generalization |
|
|
From: SeparatorSampleAcquisition. 0..1To: ProductionWellTest Association |