29.15.18 ProductionOperationWaterCleaningQuality

Topic Version1Published12/09/2016
For StandardPRODML v2.0
Type:ClassStereotype:«XSDcomplexType»

Information about the contaminants in water, and the general water quality. The values are measured from a sample, which is described below. Values measured from other samples should be given in different instances of the type.

Table 29.15.18-1 Attributes

Name

Type

Notes

Ammonium

MassPerVolumeMeasure

The amount of ammonium found in the water sample.

AmountOfOil

MassMeasure

Total measured oil in the water after the water cleaning process, but before it is discharged from the installation

CoulterCounter

MassPerMassMeasure

A measure of the number of particles in water as measured by a coulter counter.

Glycol

MassPerVolumeMeasure

The amount of glycol found in the water sample.

OilInWaterProduced

MassPerMassMeasure

Total measured oil in the water after the water cleaning process, but before it is discharged from the installation.

Oxygen

MassPerMassMeasure

Total measured oxygen in the water after the water cleaning process, but before it is discharged from the installation.

Phenol

MassPerVolumeMeasure

The amount of phenol found in the water sample.

PhValue

DimensionlessMeasure

The pH value of the treated water. The pH value is best given as a value, with no unit of measure, since there are no variations from the pH.

ResidualChloride

MassPerMassMeasure

Total measured residual chlorides in the water after the water cleaning process, but before it is discharged from the installation.

SamplePoint

String64

An identifier of the point from which the sample was taken. This is an uncontrolled string value, which should be as descriptive as possible.

TotalOrganicCarbon

MassPerMassMeasure

The amount of total organic carbon found in the water. The water is under high temperature and the carbon left is measured.

Turbidity

DimensionlessMeasure

A measure of the cloudiness of water caused by suspended particles.

uid

String64

A unique identifier for this data element. It is not globally unique (not a uuid) and only need be unique within the context of the parent top-level object.

WaterTemperature

ThermodynamicTemperatureMeasure

The temperature of the water before it is discharged.

Table 29.15.18-2 Associations

Association

Notes

From: ProductionOperationWaterCleaningQuality.Comment

0..*To: DatedComment

Association

 

From: ProductionOperationActivity.WaterCleaningQuality

0..*To: ProductionOperationWaterCleaningQuality

Association