29.21.20 WellTestBottomholeData

Topic Version1Published12/09/2016
For StandardPRODML v2.0
Type:ClassStereotype:«XSDcomplexType»

Well test data gathered at the bottomhole.

Table 29.21.20-1 Attributes

Name

Type

Notes

BottomholeMD

MeasuredDepthCoord

The measured depth of the bottomhole.

BottomholePOverZ

PressureMeasure

The P/Z value at the bottomhole. This is P/Z, pressure over gas compressibility factor (z), at the bottomhole of the well. Note that the UOM is units of pressure, because Z is dimensionless.

BottomholePres

PressureMeasure

The pressure at the bottomhole of the well.

BottomholeTemp

ThermodynamicTemperatureMeasure

The temperature at the bottomhole of the well.

WellboreReference

DataObjectReference

Defines the wellbore (sidetract) represented by the measured depth. This must be given when the well has multiple wellbores and the measured depth value is deeper than the first kickoff point. It is recommended that it always be given.

Table 29.21.20-2 Associations

Association

Notes

From: WellTestProductionTestData.BottomholeData

0..1To: WellTestBottomholeData

Association