12.8.5 Hse

Topic Version1Published11/11/2016
For StandardWITSML v2.0
Type:ClassStereotype:«XSDcomplexType»

Operations Health, Safety and Environment Schema. Captures data related to HSE events (e.g., tests, inspections, meetings, and drills), test values (e.g., pressure tested to), and/or incidents (e.g., discharges, non-compliance notices received, etc.).

Table 12.8.5-1 Attributes

Name

Type

Notes

Comments

String2000

Comments and remarks.

DaysIncFree

TimeMeasure

Incident free duration (commonly in days).

FluidDischarged

VolumeMeasure

Daily whole mud discarded.

LastAbandonDrill

TimeStamp

Last abandonment drill.

LastBopDrill

TimeStamp

Last blow out preventer drill.

LastBopPresTest

TimeStamp

Last blow out preventer pressure test.

LastCsgPresTest

TimeStamp

Last casing pressure test date and time.

LastDiverterDrill

TimeStamp

Last diverter drill.

LastFireBoatDrill

TimeStamp

Last fire or life boat drill.

LastRigInspection

TimeStamp

Last rig inspection/check.

LastSafetyInspection

TimeStamp

Last safety inspection.

LastSafetyMeeting

TimeStamp

Last safety meeting.

LastTripDrill

TimeStamp

Last trip drill.

NextBopPresTest

TimeStamp

Next blow out preventer pressure test.

NonComplianceIssued

boolean

Inspection non-compliance notice served?

Values are "true" (or "1") and "false" (or "0").

NumStopCards

int

Number of health, safety and environment incidents reported.

PresAnnular

PressureMeasure

Blow out preventer annular preventer pressure tested to.

PresChokeLine

PressureMeasure

Choke line pressure tested to.

PresChokeMan

PressureMeasure

Choke line manifold pressure tested to.

PresDiverter

PressureMeasure

Blow out preventer diverter pressure tested to.

PresKellyHose

PressureMeasure

Kelly hose pressure tested to.

PresLastCsg

PressureMeasure

Last casing pressure test pressure.

PresRams

PressureMeasure

Blow out preventer ram pressure tested to.

PresStdPipe

PressureMeasure

Standpipe manifold pressure tested to.

RegAgencyInsp

boolean

Governmental regulatory inspection agency inspection?

Values are "true" (or "1") and "false" (or "0").

VolCtgDischarged

VolumeMeasure

Volume of cuttings discharged.

VolOilCtgDischarge

VolumeMeasure

Oil on cuttings daily discharge.

WasteDischarged

VolumeMeasure

Volume of sanitary waste discharged.

Table 12.8.5-2 Associations

Association

Notes

From: Hse.Incident

0..*To: Incident

Association

Incident report occurrences description.

From: OpsReport.Hse

0..1To: Hse

Association

Health, safety and environmental information.