12.8.5 Hse
Topic Version | 1 | Published | 11/11/2016 | ||
For Standard | WITSML v2.0 | ||||
Type: | Class | Stereotype: | «XSDcomplexType» |
Operations Health, Safety and Environment Schema. Captures data related to HSE events (e.g., tests, inspections, meetings, and drills), test values (e.g., pressure tested to), and/or incidents (e.g., discharges, non-compliance notices received, etc.).
Name |
Type |
Notes |
---|---|---|
Comments |
String2000 |
Comments and remarks. |
DaysIncFree |
TimeMeasure |
Incident free duration (commonly in days). |
FluidDischarged |
VolumeMeasure |
Daily whole mud discarded. |
LastAbandonDrill |
TimeStamp |
Last abandonment drill. |
LastBopDrill |
TimeStamp |
Last blow out preventer drill. |
LastBopPresTest |
TimeStamp |
Last blow out preventer pressure test. |
LastCsgPresTest |
TimeStamp |
Last casing pressure test date and time. |
LastDiverterDrill |
TimeStamp |
Last diverter drill. |
LastFireBoatDrill |
TimeStamp |
Last fire or life boat drill. |
LastRigInspection |
TimeStamp |
Last rig inspection/check. |
LastSafetyInspection |
TimeStamp |
Last safety inspection. |
LastSafetyMeeting |
TimeStamp |
Last safety meeting. |
LastTripDrill |
TimeStamp |
Last trip drill. |
NextBopPresTest |
TimeStamp |
Next blow out preventer pressure test. |
NonComplianceIssued |
boolean |
Inspection non-compliance notice served? Values are "true" (or "1") and "false" (or "0"). |
NumStopCards |
int |
Number of health, safety and environment incidents reported. |
PresAnnular |
PressureMeasure |
Blow out preventer annular preventer pressure tested to. |
PresChokeLine |
PressureMeasure |
Choke line pressure tested to. |
PresChokeMan |
PressureMeasure |
Choke line manifold pressure tested to. |
PresDiverter |
PressureMeasure |
Blow out preventer diverter pressure tested to. |
PresKellyHose |
PressureMeasure |
Kelly hose pressure tested to. |
PresLastCsg |
PressureMeasure |
Last casing pressure test pressure. |
PresRams |
PressureMeasure |
Blow out preventer ram pressure tested to. |
PresStdPipe |
PressureMeasure |
Standpipe manifold pressure tested to. |
RegAgencyInsp |
boolean |
Governmental regulatory inspection agency inspection? Values are "true" (or "1") and "false" (or "0"). |
VolCtgDischarged |
VolumeMeasure |
Volume of cuttings discharged. |
VolOilCtgDischarge |
VolumeMeasure |
Oil on cuttings daily discharge. |
WasteDischarged |
VolumeMeasure |
Volume of sanitary waste discharged. |
Association |
Notes |
---|---|
From: Hse.Incident 0..*To: Incident Association |
Incident report occurrences description. |
From: OpsReport.Hse 0..1To: Hse Association |
Health, safety and environmental information. |