12.9.1 Bop
| Topic Version | 1 | Published | 11/11/2016 | ||
| For Standard | WITSML v2.0 | ||||
| Type: | Class | Stereotype: | «XSDcomplexType» | ||
Rig blowout preventer (BOP) schema.
|
Name |
Type |
Notes |
|---|---|---|
|
Accumulator |
String64 |
Type of accumulator/description. |
|
CapAccFluid |
VolumeMeasure |
Accumulator fluid capacity. |
|
DescControlManifold |
String2000 |
Description of the control system. |
|
DiaDiverter |
LengthMeasure |
Diameter of the diverter. |
|
DTimInstall |
TimeStamp |
Date and time the BOP was installed. |
|
DTimRemove |
TimeStamp |
Date and time of the BOP was removed. |
|
IdBoosterLine |
LengthMeasure |
Inner diameter of the booster line. |
|
IdChkLine |
LengthMeasure |
Inner diameter of the choke line. |
|
IdKillLine |
LengthMeasure |
Inner diameter of the kill line. |
|
IdSurfLine |
LengthMeasure |
Inner diameter of the surface line. |
|
LenBoosterLine |
LengthMeasure |
Length of the booster line along the riser. |
|
LenChkLine |
LengthMeasure |
Length of the choke line along the riser. |
|
LenKillLine |
LengthMeasure |
Length of the kill line. |
|
LenSurfLine |
LengthMeasure |
Length of the surface line the along riser. |
|
Manufacturer |
String64 |
Manufacturer or supplier of the item. |
|
Model |
String64 |
Manufacturer's designated model. |
|
NameTag |
NameTag |
An identification tag for the blowout preventer. A serial number is a type of identification tag; however, some tags contain many pieces of information.This element only identifies the tag and does not describe the contents. |
|
OdBoosterLine |
LengthMeasure |
Outer diameter of the booster line. |
|
OdChkLine |
LengthMeasure |
Outer diameter of the choke line. |
|
OdKillLine |
LengthMeasure |
Outer diameter of the kill line. |
|
OdSurfLine |
LengthMeasure |
Outer diameter of the surface line. |
|
PresAccOpRating |
PressureMeasure |
Accumulator operating pressure rating. |
|
PresAccPreCharge |
PressureMeasure |
Accumulator pre-charge pressure. |
|
PresBopRating |
PressureMeasure |
Maximum pressure rating of the blowout preventer. |
|
PresChokeManifold |
PressureMeasure |
Choke manifold pressure. |
|
PresWorkDiverter |
PressureMeasure |
Working rating pressure of the component. |
|
RotBop |
boolean |
Is this a rotating blowout preventer? Values are "true" (or "1") and "false" (or "0"). |
|
SizeBopSys |
LengthMeasure |
Maximum tubulars passable through the blowout preventer. |
|
SizeConnectionBop |
LengthMeasure |
Size of the connection to the blowout preventer. |
|
TypeChokeManifold |
String64 |
Type of choke manifold. |
|
TypeConnectionBop |
String64 |
Type of connection to the blowout preventer. |
|
TypeControlManifold |
String64 |
The blowout preventer control system. |
|
TypeDiverter |
String64 |
Diverter description. |
|
VolAccPreCharge |
VolumeMeasure |
Accumulator pre-charge volume |
|
Association |
Notes |
|---|---|
|
From: Bop.BopComponent 0..*To: BopComponent Association |
Container element for Blow Out Preventer component schema elements. |
|
From: RigUtilization.Bop 0..1To: Bop Association |
Blow out preventer description and components. |