12.11.33 StimPumpFlowBackTestStep
Topic Version | 1 | Published | 11/11/2016 | ||
For Standard | WITSML v2.0 | ||||
Type: | Class | Stereotype: | «XSDcomplexType» |
In a step-down pump diagnostics test, this object contains all the data for a particular step in that test.
Name |
Type |
Notes |
---|---|---|
BottomholeRate |
VolumePerTimeMeasure |
Bottomhole flow rate for the specific step. |
DTim |
TimeStamp |
Time stamp of the pressure measurement. |
EntryFriction |
PressureMeasure |
Calculated entry friction accounting for perforation and near wellbore restrictions for the specific step. |
ExtensionNameValue |
ExtensionNameValue |
Extensions to the schema based on a name-value construct. |
FlowbackVolume |
VolumeMeasure |
Volume of flowback since the start of the test. |
FlowbackVolumeRate |
VolumePerTimeMeasure |
Flowback rate. |
NearWellboreFriction |
PressureMeasure |
Calculated near-wellbore friction loss. |
Number |
NonNegativeLong |
The number of the step. Identifies the step within the step down test. |
PerfFriction |
PressureMeasure |
Calculated perforation friction for the specific step. |
PipeFriction |
PressureMeasure |
Calculated pipe friction for the specific step. |
Pres |
PressureMeasure |
Surface pressure measured for the specific step. |
SurfaceRate |
VolumePerTimeMeasure |
Surface rate entering the well for the specific step. |
uid |
String64 |
Unique identifier for this instance of StimPumpFlowBackTestStep. |
Association |
Notes |
---|---|
From: StimPumpFlowBackTest.Step 0..*To: StimPumpFlowBackTestStep Association |