12.3.8 CementJobEvaluation
| Topic Version | 1 | Published | 11/11/2016 | ||
| For Standard | WITSML v2.0 | ||||
| Type: | Class | Stereotype: | «XSDcomplexType» | ||
A top-level object that is used to record the testing and evaluation of a previously performed cement job.
|
Name |
Type |
Notes |
|---|---|---|
|
CblBondQual |
boolean |
Cement bond log quality indication? Values are "true" (or "1") and "false" (or "0"). |
|
CblPres |
PressureMeasure |
Cement bond log under pressure. |
|
CblRun |
boolean |
Cement bond log run? Values are "true" (or "1") and "false" (or "0"). |
|
CementFoundOnTool |
boolean |
Cement found on tool? Values are "true" (or "1") and "false" (or "0"). |
|
CementShoeCollar |
boolean |
Cement found between shoe and collar? Values are "true" (or "1") and "false" (or "0"). |
|
CetBondQual |
boolean |
Cement evaluation tool bond quality? Values are "true" (or "1") and "false" (or "0"). |
|
CetRun |
boolean |
Cement evaluation tool run? Values are "true" (or "1") and "false" (or "0"). |
|
ETimBeforeTest |
TimeMeasure |
Hours before the liner top test. |
|
ETimCementLog |
TimeMeasure |
Hours before logging run after cement run. |
|
ETimPitStart |
TimeMeasure |
Hours between end of cement job and the start of the pressure integrity test. |
|
ETimTest |
TimeMeasure |
Elapsed tome to perform the test. |
|
FailureMethod |
String64 |
Method used to determine that a cement job was unsuccessful. |
|
FormPit |
ForcePerVolumeMeasure |
Pressure integrity test/leak-off test formation breakdown gradient or absolute pressure. |
|
JobRating |
String64 |
Job rating. |
|
LinerLap |
LengthMeasure |
Liner overlap length. |
|
LinerTop |
LengthMeasure |
The distance to the top of the liner. |
|
MdCementTop |
MeasuredDepthCoord |
Measured depth at top of cement. |
|
MdDVTool |
MeasuredDepthCoord |
Measured depth to the diverter tool. |
|
NumRemedial |
int |
Number of remedials. |
|
PresTest |
PressureMeasure |
Test pressure. |
|
RemedialCement |
boolean |
Remedial cement required? Values are "true" (or "1") and "false" (or "0"). |
|
TempSurvey |
boolean |
Temperature survey run? Values are "true" (or "1") and "false" (or "0"). |
|
TestNegativeEmw |
MassPerVolumeMeasure |
Equivalent mud weight. Negative test. |
|
TestNegativeTool |
String64 |
Test negative tool used for the liner top seal. |
|
TestPositiveEmw |
MassPerVolumeMeasure |
Equivalent mud weight. Positive test or absolute pressure . |
|
TestPositiveTool |
String64 |
Test positive tool for liner top seal. |
|
TocOK |
boolean |
Is the top of cement sufficient? Values are "true" (or "1") and "false" (or "0"). |
|
ToolCompanyPit |
String64 |
Tool name for the pressure integrity test. |
|
TopCementMethod |
String64 |
Method to determine cement top. |
|
Association |
Notes |
|---|---|
|
From: CementJobEvaluation. To: CementJob Association |
|
|
From: CementJobEvaluation. To: AbstractObject Generalization |